Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Sci Total Environ ; 924: 171042, 2024 May 10.
Artigo em Inglês | MEDLINE | ID: mdl-38369150

RESUMO

The emergence of COVID-19 caused by the coronavirus SARS-CoV-2 has prompted a global pandemic that requires continuous research and monitoring. This study presents a design of an electrochemical biosensing platform suitable for the evaluation of monoclonal antibodies targeting the SARS-CoV-2 nucleocapsid (N) protein. Screen-printed carbon electrodes (SPCE) modified with gold nanostructures (AuNS) were applied to design a versatile and sensitive sensing platform. Electrochemical techniques, including electrochemical impedance spectroscopy (EIS) and square wave voltammetry (SWV), were used to investigate the interactions between immobilised recombinant N (rN) protein and several monoclonal antibodies (mAbs). The electrochemical characterisation of SPCE/AuNS/rN demonstrated a successful immobilisation of rN, enhancing the electron transfer kinetics. Affinity interactions between immobilised rN and four mAbs (mAb-4B3, mAb-4G6, mAb-12B2, and mAb-1G5) were explored. Although mAb-4B3 showed some non-linearity, the other monoclonal antibodies exhibited specific and well-defined interactions followed by the formation of an immune complex. The biosensing platform demonstrated high sensitivity in the linear range (LR) from 0.2 nM to 1 nM with limits of detection (LOD) ranging from 0.012 nM to 0.016 nM for mAb-4G6, mAb-12B2, and mAb-1G5 and limits of quantification (LOQ) values ranging from 0.035 nM to 0.139 nM, as determined by both EIS and SWV methods. These results highlight the system's potential for precise and selective detection of monoclonal antibodies specific to the rN. This electrochemical biosensing platform provides a promising route for the sensitive and accurate detection of monoclonal antibodies specific to the rN protein.


Assuntos
Técnicas Biossensoriais , COVID-19 , Humanos , SARS-CoV-2 , Anticorpos Monoclonais , Limite de Detecção , Técnicas Eletroquímicas/métodos , Carbono , Técnicas Biossensoriais/métodos , Eletrodos
2.
Clin Interv Aging ; 15: 1917-1925, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-33116446

RESUMO

PURPOSE: Spectral tissue Doppler-derived E/e' ratio has been proposed as the best parameter for prediction of atrial fibrillation (AF). Relaxation and contraction are equivalent parts of a continuous cardiac cycle, where systolic and diastolic abnormalities have a variable contribution to the left ventricle (LV) failure. The aim of this study was to investigate whether the E/(e'xs') ratio is a better index than E/e' to predict AF recurrence and to determine the changes of spectral tissue Doppler indices 1 month after the electrical cardioversion (ECV). PATIENTS AND METHODS: The study included 77 persistent AF patients with restored sinus rhythm (SR) after ECV. Only patients with normal LV ejection fraction (EF) were included. Echocardiography and NT-proBNP laboratory findings were performed. A primary outcome was the early (within 1 month) recurrence of AF. RESULTS: After a 1 month follow-up period, 39 patients (50.6%) were in SR. E/e' (HR=1.74, P=0.001) and E/(e'×s') ratios (HR=8.17, P=0.01) were significant predictors of AF recurrence. E/(e'×s') in combination with LV end-diastolic diameter >49.3 mm and NT-proBNP >2000 ng/L demonstrated a higher contribution in the model to predict AF recurrence compared to the E/e' ratio (18.94, P=0.005 vs 1.95, P=0.001). On ROC analysis, E/(e'×s') and E/e' showed similar diagnostic accuracy (E/(e'×s'), AUC=0.71, P=0.002 and E/e', AUC=0.75, P<0.0001). Average e' value significantly decreased after 1 month in SR (from 10.76±1.24 to 8.96±1.47 cm/s, P=0.01), E wave did not change significantly and E/e' ratio tended to improve. A decrease of average e' and an increase of average s' values led to significant improvement of E/(e'xs') ratio. CONCLUSION: E/(e'xs') and E/e' ratios are comparable to predict early AF recurrence after ECV in patients with persistent AF. The e' value decreased significantly after 1 month follow-up period after ECV for persistent AF patients.


Assuntos
Fibrilação Atrial/diagnóstico por imagem , Ecocardiografia Doppler/métodos , Cardioversão Elétrica/estatística & dados numéricos , Disfunção Ventricular Esquerda/diagnóstico por imagem , Idoso , Fibrilação Atrial/prevenção & controle , Ecocardiografia/métodos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Prognóstico , Curva ROC , Recidiva , Volume Sistólico , Disfunção Ventricular Esquerda/prevenção & controle
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...